Self-calibrating disc gap sensor
AGS – Adjustable Gap Sensor
The AGS sensor represents a further development of the TDC sensor. The tip can be moved forwards and backwards in an AGS, unlike a TDC where it is statically embedded in the refiner’s stator segment.
It is thus possible to calibrate it more often and faster in order to increase the sensor’s precision. This approach reduces the refiner’s downtime and lowers the total production cost.
User-friendly handling
An integrated system
The AGS sensor is an integrated system that includes:
- Disc clearance sensor (TDC)
- Temperature sensor
- Vibration sensor (high frequency/TVD)
- Conductance sensor
- Stepping motor that handles the movement of the tip
The system is user-friendly and the calibration is not affected by the operator.
-
The service panel (the Panel PC)
A Panel PC steers the calibration process and informs the operator about the calibration steps. The operator then chooses to accept or reject the new calibration.
-
Areas of use
AGS sensors can be used for all types of refiners that currently use TDC sensors, with the exception of Double Disc refiners. The tip is identical to that of a TDC sensor, and an AGS can be used with an RMS, RS1 or GMS measuring system.
-
Exchange of tips
The tip, which wears down at the same pace as the grinding plates, is easily replaced during segment change. The system has a built-in user-friendly guide for the tip change.
Specifications
Technical data
| Sensor principle | Reluctance sensor |
|---|---|
| Measuring range | 0–3 mm |
| Response time | 500 ms |
| Accuracy | ± 0.03 mm ± 1% of current value |
| Resolution | 0.01 mm |
| Temperature range (tip/house) | 0–220/75 ºC |
| Materials | Stainless steel, bronze, plastics and aluminum |
| Mechanical dimensions | Depending on model |
| The AGS house W×H×L | W 80, H 180, L 150 mm |
| Diameter of the holder | 45–55 mm |
| Diameter of the measuring tip | 25/27 mm |
| Distance to supporting edge | 23/30 mm |
| Total length | 350–653 mm |
| Weight | 2.5–8.0 kg |
FAQ
Frequently asked questions
What is the difference between a TDC and an AGS sensor?
Can the AGS sensor be calibrated during production?
How often should the AGS sensor be calibrated?
Does the operator need to supervise AGS calibration?
How do you replace the tip on an AGS sensor?
Can we switch from TDC to AGS on existing refiners?